Measurements of Sound Power

Norsonic can offer a set of tools, both hardware and software, to perform a wide range of relevant EU and international product test standards. Our certified sound power testing solutions will help you with engineering and benchmarking issues in your R&D department, but also to assure that your product comply the requirements of the standards.

Norsonic offers 3 years warranty.

Products

Nor145 Single Channel Sound Analyser

Nor145 Single Channel Sound Analyser

The Nor145 (single channel) and Nor150 (dual channel) sound analysers sets new standards in user-friendliness and sophistication not yet found in any other sound level meter on the market today. Featuring a large 4.3” true colour touchscreen sharing the same user philosophy as a smartphone.

The Nor145 and Nor150 are based on the same hardware and software platform and are in its basic configuration equal. Different emphasis has been made to optimize the use of the two models.

The Nor145 is a single channel unit optimized for easy wireless connectivity featuring a built-in 3G/4G/LTE and WLAN modem. It is smaller and lighter than the Nor150.

Connect your smartphone, pad or PC and take full control of the instrument. Add photos and voice notes obtained on your smartphone or pad seamless integrated with markers to your noise data.

Applications:

  • Environmental noise assessments
  • Building acoustics
  • Room acoustics – STIPA
  • Sound intensity (Nor 150 only)
  • Noise monitoring
  • Product noise testing
  • Vibration measurements
  • Noise in the workplace
  • Infrasound
  • Ultrasound
  • Noise nuisance recorder
  • Front end for Nor850

 

Features:

  • Precision sound level meter and frequency analyser according to class 1.
  • Easy connectivity via built in WLAN and 3G/4G. LTE modem (Nor145).
  • Dual channel (Nor150 only).
  • Large colour touchscreen (4.3”).
  • Real push keys for quick operation in challenging environments.
  • Intuitive user interface with graphical icons for selection of measurement mode and custom-made user setups.
  • Voice, text notes and built-in GPS for documentation of the measurements.
  • Wide frequency range (0,4 Hz – 40 kHz in 1/3 octave band and FFT).
  • Parallel 1/3 octaves and FFT analysis.
  • 120 dB measurement range.
  • Extensive trigger system for reports, audio recording and camera.
  • Seamless integration with Nor850 software.
  • Multi language support.
  • Extensive on-board help system.

 

For complete specification and demo of the device, contact us via our contact form.

Nor150 Dual Channel Sound Analyser

Nor150 Dual Channel Sound Analyser

The Nor145 (single channel) and Nor150 (dual channel) sound analysers sets new standards in user-friendliness and sophistication not yet found in any other sound level meter on the market today. Featuring a large 4.3” true colour touchscreen sharing the same user philosophy as a smartphone.

The Nor145 and Nor150 are based on the same hardware and software platform and are in its basic configuration equal. Different emphasis has been made to optimize the use of the two models.

The Nor150 is a dual channel instrument suitable for all dual channel applications such as Sound intensity measurements and dual channel building acoustics. The Nor150 cannot be fitted with a built-in 4G/LTE and WLAN modem but can be easy interfaced to use external devices for this purpose. Further features include built-in web server, camera, GPS and advanced voice and text notes bringing the sophistications normally found in laboratory instrumentation out in the field.

Connect your smartphone, pad or PC and take full control of the instrument. Add photos and voice notes obtained on your smartphone or pad seamless integrated with markers to your noise data.

Applications:

  • Environmental noise assessments
  • Building acoustics
  • Room acoustics – STIPA
  • Sound intensity (Nor 150 only)
  • Noise monitoring
  • Product noise testing
  • Vibration measurements
  • Noise in the workplace
  • Infrasound
  • Ultrasound
  • Noise nuisance recorder
  • Front end for Nor850

 

Features:

  • Precision sound level meter and frequency analyser according to class 1.
  • Easy connectivity via built in WLAN and 3G/4G. LTE modem (Nor145).
  • Dual channel (Nor150 only).
  • Large colour touchscreen (4.3”).
  • Real push keys for quick operation in challenging environments.
  • Intuitive user interface with graphical icons for selection of measurement mode and custom-made user setups.
  • Voice, text notes and built-in GPS for documentation of the measurements.
  • Wide frequency range (0,4 Hz – 40 kHz in 1/3 octave band and FFT).
  • Parallel 1/3 octaves and FFT analysis.
  • 120 dB measurement range.
  • Extensive trigger system for reports, audio recording and camera.
  • Seamless integration with Nor850 software.
  • Multi language support.
  • Extensive on-board help system.

 

For complete specification and demo of the device, contact us via our contact form.

Nor850 Multi-Channel Measurement System

Nor850 Multi-Channel Measurement System

The Nor850 measurement system is the state-of-the-art acoustical analyser from Norsonic. Using the experiences and accumulated knowhow from the previous generations of analysers such as Nor811, Nor823, Nor830 and Nor840, Norsonic is offering a multi-channel system with focus on user friendliness, high efficiency and accurate reporting. The system has been designed for field testing as well as demanding accredited lab measurements.

The software Nor850 Suite is connecting a variable number of individual measuring units to create the optimal system that suits the desired measurement task. Dedicated user-friendly apps offer the following application packages:

  • General Analyzer;
  • Building Acoustic;
  • Room Acoustics;
  • Sound Power;
  • Appliance Noise.

 

Nor850-MF1

The Nor850-MF1 rack is delivered with a selectable number of measurement channels, and may be upgraded with additional channels as the needs grow. One rack can be fitted with up to ten channels. Multiple racks may be used in the same system alternatively in a mix with Nor140, Nor145 or Nor150 Sound Level Meters as additional frontends. Optionally, selected channels may be fitted with signal generator outputs.

General Analyser Mode

The General Mode allows you to make multispecter measurements in all channels simultaneously with various settings for frequency range and level profiles. The profiles have user-defined period lengths from a few msec to several minutes. The results are presented in user-defined setups with both level vs. frequency and level vs. time views as well as tables. Special views for 3D or Spectrogram are also available.

Quality control measurements are easily made using the two reference spectra possibilities. Each reference spectre may be used as a lower or upper boundary with a Go/NoGo output to the operator.

The Nor850 Suite offers an environmental software extension that enables the user to make audio recordings in selected channels and to insert event markers along the timeline during the measurement sequence.

Available features for all modes
In the heart of the Nor850 Suite there is a sensor database containing all possible information about each users complete list of measurement transducers (microphones, preamplifiers, accelerometers, etc.) including serial numbers, product name, producer, calibration history, verification laboratories, the date of next verification, correction data, and more. The data base may also include similar data for calibrators and reference sound sources.

Logging of DC-voltage levels in parallel with the acoustic measurements is available, as well as direct read-in of temperature, humidity and pressure from external sensors.

Individual units for each measuring channel offer a very high degree of operating flexibility. It allows the user to operate a multichannel system one day – or many individual measuring units another day!

The multichannel system Nor850 is expanding as the needs grow. Start with the new Nor150 SLM, or two units of the Nor140 or 145 SLM’s, and increase step-by-step by adding additional SLM units – or mix with Nor850-MF1 Racks containing 1-10 measuring channels.

By connecting a number of individual measuring units through various communication channels – including both LAN and USB – the user may create the optimal multichannel system for any task. Wireless communication through Bluetooth or WLAN is also available.

Each individual measuring unit may be homologated by independent verification laboratories.

Building Acoustics Mode
The basic Building Acoustics application package includes all required features for performing sound insulation tests in the field. Both the traditional ISO 140 Standards as well as the new ISO 16283 Standards are included, plus national varieties of these. The ASTM Standards E336, E90 as well as the E413 are also included.

In the extended Building Acoustics package, the more advanced laboratory test such as ISO 10140 as well as ASTM E1007, E492 and E989 are included together with absorption coefficient testing in accordance with ISO 354 and ASTM C423.

The signal generator offers white, pink or bandpass filtered noise even with user defined pre-excitation of the measurement chambers. The Nor850 Suite additionally offer features for automatic control of Rotating Microphone Booms, Tapping Machines as well as control of moving loudspeaker systems.

Calculation of sound insulation indices with predefined printed reports as well as parameter input in both metric and US formats. Enhanced features for multichannel calibration procedures are available using remote displays and acoustic loudspeaker feedback.

Old measurement project from previous Norsonic analysers may be imported and compared with new measurements using the multi-project feature. Measurement results are re-used in new projects by easy drag&drop functionality.

Room Acoustics Mode
The new room acoustics module 850/RA offers the complete evaluation according to EN ISO 3382-2 (ordinary rooms) and EN ISO 3382-3 (open-plan offices).

The reverberation time T for the evaluation according to EN ISO 3382-2 can be measured via the impulse or noise excitation, either first in the sound level meter or directly via the Nor850 software – with wireless control of the Nor145 sound level meter and power amplifier via WLAN.

In addition to the evaluation according to EN ISO 3382-2, the Module also enables the measurement of the room impulse response using the SweptSine excitation followed by calculation of the reverberation time and speech intelligibility, as well as the complete measurement routine and evaluation for open-plan offices according to ISO 3382- 3, including generating the test report with all single values (D2,S; Lp,A,S,4m; rD, rC, Lp,A,B).

Completely wireless – no more hassle with cables!

Sound Power Mode

  • ISO 374x series.
  • ISO 6395.
  • Customized adaptions to other standards.
  • Turn-key solutions.
  • Scheduler for time saving testing and increased quality.
  • Wlan communication or cable from measurement points to host.

 

The basic Sound Power application package includes all features required for making sound power test in accordance with the ISO 374x series.

The extended Sound Power application package contains required features for making more special tests such as dual-chamber testing of heat-pumps, dynamic testing of earth moving machinery in accordance to ISO6395 and similar. The entire test procedure can be controlled by a user programable Scheduler to minimize attended test personnel and increased quality. Norsonic offers turn key solutions and customized adaptions.

Wlan communication from the measurement points may be used in larger test setup in accordance with ISO 6395 to save cabling cost.

Appliance Noise Mode
Water below atmospheric pressure create vapor at lower temperature. Large pressure differences appear across small volumes of turbulent water. Here bubbles are created, and they collapse when they reach a region of higher pressure. This creates a disturbing amount of acoustic noise distributed through the tubes.

Standardized measurements are needed to compare the noise emitted from different products. The Appliance Noise application package includes the required features to perform a full laboratory test in accordance with the ISO 3822, Noise emission from appliances and equipment used in water supply installations.

The Norsonic Nor850 multi channel noise analyser is the perfect sound power measurement tool for use both in R&D and on production lines for any industry or test lab dealing with water appliances.

The optional Nor850/DC module measures water flow, water pressure, temperature, and other required parameters automatically to speed up the test.

  • Highly configurable.
  • Easy setup.
  • Intuitive and efficient interface.
  • Test Scheduler for automated processes.
  • Customized report generator.
  • Automatically read in of waterflow, temperature, pressure etc.
  • For both experts and freshmen.
  • ISO 3822 and EN12541 compatible.

 

For complete specification and demo of the product, contact us via our contact form.

Nor278 Reference Sound Source

Nor278 Reference Sound Source

  • Substitution and juxtaposition methods for determination of sound power of noise sources according to ISO 3747.
  • Comparison method for determination of sound power of noise sources according to ISO 3741, ISO 3743-1, ISO 3744 and 3747.
  • A-weighted Sound power output: 93dB re 1 pW (50Hz line frequency).
  • Sound power 50 Hz – 20 kHz: 94dB re 1 pW (50Hz line frequency).
  • Fulfils ISO 6926 for reference sound sources in the extended frequency range 50 Hz – 10 kHz.
  • Accredited calibrated.
  • Long-term stability.
  • Weight 18,6 kg
  • Rugged.

 

For complete specification and demo of the device, contact us via our contact form.

Nor850 Reporting software

Nor850 Reporting software

Create professional reports fast, accurate and easy. Instead of using your own created excel reports, spending time on maintaining it to the latest revision of standards, try out the Nor850 reporting software. This ensures you make accurate and up to date reports at a glance.

The Nor850 reporting software takes advantage of the modules used in the Nor850 measurement system but offered as individual reporting and post processing packages for

  • Building Acoustic
  • Room Acoustics
  • Sound Power
  • Sound Intensity

 

Measurements taken manually by use of the Norsonic sound level meters Nor140, Nor145 or Nor150 are easily imported into the reporting modules. The powerful multi project tool allows you to easily search across projects to extract and work with data from multiple projects. The Nor850 Reporting system can be upgraded to a complete Nor850 Measurement system at any time.

Building Acoustics
Level, reverberation and background measurement files are placed into the respective table folders by simple drag & drop technique. Even complete building acoustics files containing all data in one file may be imported. The full range of Standards for building acoustics such as the in-situ ISO 16283, laboratory ISO 10140, ISO 717, and service equipment ISO 10052 as well as national version such as American ASTM Standards, are selectable.

Room Acoustics
The reporting module for room acoustic supports the open plan office standards ISO 3382-2 and -3.

Sound Power
The sound power module supports the ISO 374x series of standards. Calculation properties as well as informative text for the excel reports are inserted and edited for the final calculation of the sound insulation indices or sound power value.

Sound Intensity
The sound intensity reporting module supports ISO 9614-1 and -2 and the Sound intensity transmission loss in accordance with ISO 15186-2.

For complete specification and demo of the product, contact us via our contact form.

Nor265A Microphone Boom

Nor265A Microphone Boom

  • Oscillating microphone boom for spatial averaging in building acoustics or sound power measurements.
  • Building acoustics measurements in accordance with ISO 10140 and ISO 16283.
  • Reverberation time measurements in accordance with ISO 354.
  • Sound Power measurements in accordance with ISO 3740 series.
  • Directional response measurements of loudspeakers and microphones.
  • Accurate positioning.
  • Sweep of ±90º and ±180º.
  • Direct control or remote control from a PC via LAN interface.
  • User defined sweeps. Selectable sweep times.
  • Supported by Nor850.
  • LAN interface.
  • Nor265 may be equipped with a turntable (optionally).

 

For complete specification and demo of the product, contact us via our contact form.

NorVirtual / NorVirtual App

NorVirtual / NorVirtual App

NorVirtual emulates the Nor13x, Nor140, Nor145 and Nor150 on a PC. Freeware.

NorVirtual App for smartphones emulates the Nor145 and Nor150. It is a 1:1 copy of the screen and keyboard of the instrument. Whatever view the sound level meter has (graphs, menus, tables etc.), the same view is visible on the device screen. The mouse can be used to operate the virtual keyboard.

NorVirtual for Nor145/Nor150 supports all communication channels. Hence, you may connect to a Nor145/Nor150 via modem, Wlan, LAN etc and use the program as a simple remote control. In combination with NorConnect you have a simple and intuitive solution for remote control and download measurements.

NorVirtual App can be downloaded from Apple Store or Google Play.

For complete specification and demo of the software, contact us via our contact form.

Send a free INQUIRY

Contact us via form or directly by e-mail info@univer.solutions




    Business information

    Business Name:

    Universal Acoustic Soultions

    Email:

    info@universalacoustic.solutions

    PIB:

    113690821

    Identification number:

    21913936